Float switches below are RAW sensor readings (can glitch) — separate from the controller level estimate above.
Water valve (CH4)OFF
Spray pump (CH7)OFF
Circulate Pump1 (CH5)OFF
Transfer Pump2 (CH6)OFF
Tank A highOFF
Tank A lowOFF
Tank B highOFF
Tank B lowOFF
🧪
Checking...
EC / pH
EC target-
pH target-
EC · pH
EC-
pH-
Water-
RZ1-
RZ2-
RZ3-
📷 View photo
EC (mS/cm)pH
Water temp · Root-zone (°C)
WaterRZ1RZ2RZ3
RZ1
-°C
RZ2
-°C
RZ3
-°C
🌡
Checking...
Temp / Humidity
Temperature · Humidity
Temp-
Humidity-
CO₂-
📷 View photo
Temp (°C)Humidity (%)Cool mist (CH4)
CO₂
CO₂ (ppm)
Temp
-°C
Humidity
-%
CO₂
-ppm
Time
Same time each day/week, oldest → newest. Slide to watch growth.
No image
---
Temp
-
Humidity
-
CO₂
-
EC
-
pH
-
Water
-
📷 Capture interval
How often a photo is taken. Shorter = more detail, more storage.
Operation Mode
EC Dosing
Nutrient A/B (CH0/1). When OFF, EC is not adjusted.
pH Dosing
pH up/down (CH2/3). When OFF, pH is not adjusted.
⚠ Manual mode active. Automatic cycle is paused. You have direct control.
💻 Display
Exit Fullscreen
Switches to windowed mode. Close browser to return to desktop.
🔋 ALT2 Controller Gateway
Sends MQTT set_relay commands. auto=0 for manual override.
CH0 EC Nutrient A
CH1 EC Nutrient B
CH2 pH Up ⚠ BROKEN
CH3 pH Down
CH4 Canopy Mist (fresh water)
CH5 Pump1 Circ.
CH6 Pump2 B→A
CH7 Spray Pump
📅 Growing season
Start date
Select date📅
Total days
🧪 Nutrient schedule
Tap a stage to edit. Shorten a stage's end day and tap Done — the remaining days become a new stage automatically.
⚗ EC / pH Deadband (ALT2 dosing)
Dosing valve activates when value passes target + deadband. Shared with ALT2 channels.
EC deadband
mS/cm (neg)
pH deadband
Stable timesec
💉 Dosing pulse
EC/pH dosing solenoid. Length = how long the valve opens per pulse. Interval = gap between pulses (mixing / spacing).
Pulse length
sec
Pulse interval
sec
💦 Spray cycle (day / night)
Spray pump repeats ON then OFF. Set different intervals for day and night.
Day starts
Night starts
☀ Daytime
Spray ON
sec
Spray OFF
sec
🌙 Nighttime
Spray ON
sec
Spray OFF
sec
🌬 Climate control (ALT2)
Control by
Open at°C
Close at°C
Humid max%
Humid min%
CO₂ maxppm
CO₂ minppm
Changes are saved automatically.
📈 Growing Trend- / -
Select a dayTouch the chart to see daily values📷 Photo
Nutr
Temp
⚠ Cannot reach the side-vent controller (:8081). It may be stopped, or not started yet after a reboot.
🌲 Side Vent — Status
—
Wind
—
Inside temp
—
Rain
—
📈 Wind · inside temp · rain · vent position
Wind-
Temp-
Rain-
Vent-
Mist-
Wind (m/s, left)Inside temp (°C, right)RainVent OPEN (top band)Cool mist
Dashed lines = wind-close / temp-open / temp-close thresholds. The top band shows when the vent was open (green) or closed (dark). Wind usually spikes before rain — watch the blue line against the purple rain shading. Cyan ticks = canopy cooling mist runs (CH4).
⚙ Mode & control
Left = mode (AUTO / MANUAL). Right = manual open / stop / close (switches to MANUAL). The motor self-limits at each end.
⏰ Schedule & conditions
Open time
h (0–23)
Close time
h (1–24)
Day: close if temp ≤
°C
Night: open if temp ≥
°C
Temp deadband
°C
Wind deadband
m/s
Day: close if wind ≥
m/s
Ignore gusts under
sec
Motor run time
sec
Saved automatically. Wind must stay high for the gust-ignore time before closing; deadbands prevent flapping near a threshold.
💦 Canopy cooling mist (CH4, fresh water)
Sprays tap water over the grow beds to knock the canopy temperature down before the daily peak (misting at peak sun risks lens-effect leaf burn). Runs also appear on the Mist tab and on the Climate temp chart so you can track the temperature drop.
Schedule mode
Skip if air temp below
°C
Skip if humidity ≥
%
Extra run if temp crosses (0=off)
°C
Guards: max 60 s per run · daily budget 240 s · only 08–17h · skips while the rain sensor reports rain. "Skip below" stops misting on cool days; "Skip if humidity" stops it on overcast/humid days — misting when it's already damp risks fungal disease (mist is only for knocking temperature down; early in a shower the warmed greenhouse can still read 60–70% RH, so the rain sensor covers that gap). The spray-failure assist mist ignores these skips (emergency relief). The optional "crossing" trigger fires one extra 30 s run the moment the air temp rises past the value.
🛡 Spray-failure watch: if the root-zone temp drifts ≥6°C above the nutrient water temp for 30 min while the root spray cycle is running, you get a Telegram alarm (the spray pump is probably not wetting the roots) and one assist mist fires.
📖 AUTO logic
Night (close–open time): closed by default; opens if temp ≥ night limit (and calm); recloses once it cools past the deadband. Day (open–close time): open by default; closes if temp ≤ day limit or wind stays high. Reopens only when both clear — calm and warm (past deadbands). Short wind gusts are ignored. Wind sensor offline → closed (fail-safe). Rain sensor is display-only. MANUAL overrides all.
CPU temp
-°C
Memory
-%
Disk
-%
Uptime
-h
MQTT connections
Relay GW Water GW Air GW
💾 Data export (CSV)
Download sensor history to back up before the 90-day auto-delete, or for analysis.